製品カタログ
アプリケーション
サポート
- AM-xxx-2mm/LD: 1.1x Pre-Aliquoted ReddyMix
- AM-xxx-2mm: 1.1x Pre-Aliquoted
- AM-xxx-4mm/LD: 1.1x Pre-Aliquoted ReddyMix
- AM-xxx-4mm: 1.1x Pre-Aliquoted
- AM-xxx-6mm/LD: 2x Pre-Aliquoted ReddyMix
- AM-xxx-6mm: 2x Pre-Aliquoted PCR
- AM-xxx-8mm/LD: 2x Pre-Aliquoted ReddyMix
- AM-xxx-8mm: 2x Pre-Aliquoted PCR
- EX-xxx-2/LD: 1.1x Pre-Aliquoted Extensor Hi-Fidelity ReddyMix
- EX-xxx-2: 1.1x Pre-Aliquoted Extensor Hi-Fidelity
- EX-xxx-4/LD: 1.1x Pre-Aliquoted Extensor Hi-Fidelity ReddyMix
- EX-xxx-4: 1.1x Pre-Aliquoted Extensor Hi-Fidelity
- EX-xxx-6/LD: 2x Pre-Aliquoted Extensor Hi-Fidelity ReddyMix
- EX-xxx-6: 2x Pre-Aliquoted Extensor Hi-Fidelity
- EX-xxx-8/LD: 2x Pre-Aliquoted Extensor Hi-Fidelity ReddyMix
- EX-xxx-8: 2x Pre-Aliquoted Extensor Hi-Fidelity
- TS-xxx-2mm: 1.1x Pre-Aliquoted
- TS-xxx-4mm: 1.1x Pre-Aliquoted
- TS-xxx-6mm: 2x Pre-Aliquoted
- TS-xxx-8mm: 2x Pre-Aliquoted
- ゲノミクス製品FAQ
- チューブ・プレート機器適合表
関連製品
PCR分注済マスターミックス
製品特長
- 操作時間を短縮
- 反応液の調製ミスを軽減
- カスタム注文
製品概要
Thermo Scientific ABgene 製品の耐熱性DNA Polymerase、バッファー、PCR チューブやプレートからご希望の組み合わせを選んでいただくセミカスタム製品です。チューブやプレートにPCR に必要な試薬があらかじめ分注された状態で製品を提供します。
保存温度
製品は-20℃で保存してください。4℃では最大4週間まで安定です。凍結融解を繰り返さないでください。
選択ガイド
ステップ1 でDNA Polymerase を選択した後、ステップ2 以降でバッファーやチューブ・PCR プレートを選択してい
きます。 選択した酵素によって、選択するステップが異なります。
| Step 1 | Step 2 | Step 3 | Step 4 | Step 5 | Step 6 | Step 7 |
| Enzyme type | EX Buffer Type | Consumable Type | Conc. & reaction | MgCl2 conc. | ReddyMix | Pack size |
| AM | choice | choice | choice | choice | choice | |
| EX | choice | choice | choice | choice | choice | |
| TS | choice | choice | choice | choice |
下記選択表のPDF版はこちら(50KB)からダウンロードしてください。
| Step 1 Enzyme type |
AM: | ThermoPrime (standard PCR) |
| EX: | Extensor (hi-fi/long PCR) | |
| TS: | Thermo-Start (hot-start PCR) | |
| Step 2 Buffer type (EX ONLY) |
1: | For templates up to 12kb |
| 2: | For templates > 12kb | |
| Step 3 Consumable type |
620: | Individual 0.2ml Flat Cap Thermo-Tubes |
| 489: | Individual 0.5ml Domed Cap Thermo-Tubes | |
| 337: | Individual 0.2ml Domed Cap Thermo-Tubes | |
| 350: | Individual 0.5ml Flat Cap Thermo-Tubes | |
| 266: | Thermo-Strips with Domed Caps (8-tube strip) | |
| 1182: | Thermo-Strips with Flat Caps (8-tube strip) | |
| 1113: | Thermo-Strips with Domed Caps (12-tube strip) | |
| 1114: | Thermo-Strips with Flat Caps (12-tube strip) | |
| 772: | Low Profile Thermo-Strips with Domed Caps (8-tube strip) | |
| 773: | Low Profile Thermo-Strips with Flat Caps (8-tube strip) | |
| 848: | Low Profile Thermo-Strips with Domed Caps (12-tube strip) | |
| 849: | Low Profile Thermo-Strips with Flat Caps (12-tube strip) | |
| 600: | ABgene 96 PCR Plate Non-Skirted, Capped | |
| 700: | ABgene 96 PCR Plate Non-Skirted, Low Profile, Capped | |
| 800: | ABgene 96 PCR Plate Skirted, Low Profile, Capped | |
| 900: | ABgene 96 PCR Plate Semi-Skirted, Capped | |
| 990: | ABgene 96 PCR Plate Rigid Semi-Skirted, Capped | |
| 1000: | ABgene 96 PCR Plate Rigid Skirted, Low Profile, Capped | |
| 1300: | ABgene 96 Robotic PCR Plate, Capped | |
| 1100: | ABgene 96 PCR Detection Plate, Capped | |
| 1400: | ABgene 96 PCR Detection Plate Mark II, Capped | |
| 2100: | ABgene SuperPlate Raised Semi-Skirt 96-Well PCR Plate, Easy Peal Heat Seal | |
| 2400: | ABgene SuperPlate Semi-Skirted 96-Well PCR Plate, Capped | |
| 2800: | ABgene SuperPlate Skirted 96-Well PCR Plate | |
| 84: | ABgene 384 PCR Plate, Easy Peel Heat Seal | |
| 937: | ABgene 384 PCR Plate Mark II, Easy Peel Heat Seal | |
| 1111: | ABgene 384 Diamond PCR Plate, Diamond Foil Seal | |
| Step 4 Conc. & final reaction volume |
2: | 1.1X concentration, 25μl final reaction volume |
| 4: | 1.1X concentration, 50μl final reaction volume | |
| 6: | 2X concentration, 25μl final reaction volume | |
| 8: | 2X concentration, 50μl final reaction volume | |
| Step 5 Final MgCl2 concentration (NOT for EX) |
15: | 1.5mM MgCl2 |
| 20: | 2.0mM MgCl2 | |
| 25: | 2.5mM MgCl2 | |
| 30: | 3.0mM MgCl2 | |
| 35: | 3.5mM MgCl2 | |
| 40: | 4.0mM MgCl2 | |
| Step 6 ReddyMix (NOT for TS) |
LD: | ReddyMix (or leave blank for standard) |
| Step 7 Pack size |
A: | 96 tubes of type 337, 620, 489 or 350 (25μl reaction volume) 96 tubes of type 337, 620, 489 or 350 (50μl reaction volume) 12 strips of type 266, 1182, 772 or 773 (25μl reaction volume) 12 strips of type 266, 1182, 772 or 773 (50μl reaction volume) 8 strips of type 1113, 1114, 848 or 849 (25μl reaction volume) 8 strips of type 1113, 1114, 848 or 849 (50μl reaction volume) |
| B: | 10 x 96 tubes of type 337, 620, 489 or 350 (25μl reaction volume) 10 x 96 tubes of type 337, 620, 489 or 350 (50μl reaction volume) 10 x 12 strips of type 266, 1182, 772 or 773 (25μl reaction volume) 10 x 12 strips of type 266, 1182, 772 or 773 (50μl reaction volume) 10 x 8 strips of type 1113, 1114, 848 or 849 (25μl reaction volume) 10 x 8 strips of type 1113, 1114, 848 or 849 (50μl reaction volume) |
|
| C: | 10 x 96-well plate of type 600, 700, 800, 900, 990, 1000, 1100, 1400, 1900, 2100, 2400, 2800 (25μl) 5 x 96-well plate of type 600, 700, 800, 900, 990, 1000, 1100, 1400, 1900, 2100, 2400, 2800 (50μl) 10 x 384-well plate of type 384, 937, 1111 (25μl) |